Electromagnetic Heat Flowmeter
Diameter: DN25 ~ DN400
Nominal pressure: 0.6MPa/1.6MPa/4.0MPa
Lining material: Neoprene, Polyurethane Rubber, F4, F46
Electrode material: 316L, Ti, HB/HC, Ta, WC, Pt
Structure type: separated type, integrated type
MPM489WZ3
Used For
Petroleum, Chemical, Power Plant, Urban Water Supply and Drainage, Hydrological Exploration
Leave a MessageThe MPM489WZ3 compact submersible level transmitter has a sealed one-piece construction for direct immersion in liquids and an amplifier circuit that converts the pressure signal into a standard current/voltage output to measure the precise level depth. 22mm diameter with stainless steel case and nylon cover. The 22 mm diameter transmitter is supplied with a stainless steel case and nylon cap, and is available in 4-20 mA and 0.5-4.5 VDC outputs.
Features
• The top shell cap is removable to prevent accidental damage to the diaphragm and facilitate regular cleaning
Specifications
• Range: 0mH2O ~ 1mH2O…7mH2O
• Overpressure: ≤ 2 times FS
• Accuracy: ±1%FS
• Long-tem Stability: ±0.5% FS/year
• Compensated Temperature: 0℃ ~ 50℃
• Application Temperature: -20℃ ~ 70℃ (cable material: PE, PVC) / -20℃ ~ 80℃ (cable material: PUR)
• Storage Temperature: -20℃ ~ 85℃
• Protection Rating: IP68
Image:
The MPM489WZ3 compact submersible level transmitter has a sealed one-piece construction for direct immersion in liquids and an amplifier circuit that converts the pressure signal into a standard current/voltage output to measure the precise level depth. 22mm diameter with stainless steel case and nylon cover. The 22 mm diameter transmitter is supplied with a stainless steel case and nylon cap, and is available in 4-20 mA and 0.5-4.5 VDC outputs.
Features
• The top shell cap is removable to prevent accidental damage to the diaphragm and facilitate regular cleaning
Specifications
• Range: 0mH2O ~ 1mH2O…7mH2O
• Overpressure: ≤ 2 times FS
• Accuracy: ±1%FS
• Long-tem Stability: ±0.5% FS/year
• Compensated Temperature: 0℃ ~ 50℃
• Application Temperature: -20℃ ~ 70℃ (cable material: PE, PVC) / -20℃ ~ 80℃ (cable material: PUR)
• Storage Temperature: -20℃ ~ 85℃
• Protection Rating: IP68
Diameter: DN25 ~ DN400
Nominal pressure: 0.6MPa/1.6MPa/4.0MPa
Lining material: Neoprene, Polyurethane Rubber, F4, F46
Electrode material: 316L, Ti, HB/HC, Ta, WC, Pt
Structure type: separated type, integrated type
Temperature Range: -30~150℃ / -22~302℉
Accuracy: ≤±1℃ (FS≤100℃ ); ≤±2℃ (FS>100℃ )
Intrinsic safe version available
1 2 3 4mH2O
Accuracy: +0.25%FS(yp.) +0.5%FS(max.)
4~20mADC,0~10/20mADC,0/1~5/10VDC/20mADC,0/1~5/10VDC
1, 2, 5, 10, 20, 50, 100, 200mH2O
Display: 4 digit 0.56 inch 14-segment LED display
Output: 4~20mA DC, 0~10V DC
Gas skid equipment is a critical component in gas distribution systems. Equipped pressure and temperature transmitters can monitor parameters in real time. Then, the data is transmitted remotely to a central control room. The engineer or operator detects abnormal situations in time. It ensures the normal operation of the equipment and system.
more info...Real-time monitoring the low-ling areas, underpasses and bridge culverts. The current level and alarming messages are automatically displayed on the screen, such as “Passage”, “Allowing”, and “No entering”. The alarm will be triggered when the level is too high, aiming to ensure the personnel's safety.
more info...Aerial work platforms utilize hydraulic equipment for platform elevation to achieve high-altitude operations. In some fields, pressure transmitters are required to enable monitoring of operating conditions and fault diagnosis capabilities.
more info...There is a shortage of freshwater resources in coastal or nearshore areas. Desalination is an important solution to water shortages in these areas. During the seawater desalination process, data such as flow rate and liquid level need to be monitored. Monitoring of these data ensures that the system is operating properly.
more info...