Geothermal Resource Monitoring Solution
2019-04-01

Background

Xiong'an New District, located in the Beijing-Tianjin-Hebei region, is rich in karst heat storage with a large amount of geothermal resources. Its heat flow value is the highest in the Jizhong sag.


Requirements

There are a large number of geothermal wells that can be controlled in Xiong'an New District. In order to realize the sustainable development of Xiong'an New District, the relevant departments will implement comprehensive control over the hot mining wells in the jurisdiction, and monitor real time flow, temperature and water level data of the hot well mined and disposal water. The specific measurement requirements are as follows:

1. Flow monitoring of the amount of mined water and returned water.

2. Temperature monitoring of the mined and returned water.

3. Water level monitoring in the mining well.

4. Real-time monitoring data transmission wirelessly and remotely to the supervision department control center.


Heat Exchange System Diagram

 

Solutions

The installation conditions of electromagnetic flow meter in the heat exchanger station:

The site is mostly a heat station that has been built and put into use. The electromagnetic flow meter and temperature transmitters can be equipped in the primary pipe network and the secondary pipe network as needed. 



Onsite


The requirements of electromagnetic flow meter installation:

 

 


1. In order to ensure the measurement accuracy of the pipe-type electromagnetic flow meter, the straight pipe sections before and after the electromagnetic flow meter should meet the requirements of a certain straight pipe section during installation. According to the test standard requirements of GJ1033-2007 "Electromagnetic Flow meter Verification Regulations", usually the front straight pipe section should reach 5D or above, and the rear straight pipe section should be 3D or above;

2. The electromagnetic flow meter can be installed vertically and horizontally. The site is mostly horizontally installed, so that the electromagnetic flow meter electrodes are at the same level and keep the pipe network full.

3. Since the electromagnetic flow meter measures the weak potential, good grounding is necessary to ensure the stable operation of the electromagnetic flow meter. Generally, the grounding is realized by the grounding ring or the reference electrode in the sensor and the grounding connection of the pipeline system;

4. There should be no strong leakage current in the pipeline installed with electromagnetic flow meter. It should be as far away as possible from equipment with strong electromagnetic fields to avoid electromagnetic field interference such as large motors, large transformers, and inverters, etc.

 

Products

According to the on-site pipe network, the solution includes MFE600 series integrated electromagnetic flow meter, supporting Earth1006 remote monitoring terminal, MPM4700 intelligent liquid level transmitter and MTM integrated temperature transmitter.





  

Cases


 

 

Real-time monitoring data of electromagnetic flow meter, temperature transmitter and liquid level transmitter is integrated into the Earth1006 remote monitoring terminal RTU through digital RS485 or analog 4-20mA, and then is transmitted to the regulatory department Data platform by using the operator's public network wireless cloud.

 

 

Visit iot.microsensor.cn to check real time data of each monitoring spots.


Certificates

MFE600 electromagnetic flow meter has approved CE and explosion-proof certificates.

 


 

Contact us

Flow rate, temperature, liquid level and RTU applied in thermal well monitoring should refer to the actual situation. Micro Sensor flow technology team will provide you customized product solution according to the site environment. Feel free to contact us via sales@microsensor.cn or leave messages.