As IMO emission regulations continue to tighten, VOC control has become a standard requirement in marine environmental protection systems. Ensuring safe, stable, and compliant operation of VOC treatment units—such as RTO systems, adsorption–desorption units, and condensation recovery equipment—requires accurate and reliable measurement across the entire process.
Micro Sensor provides precise measurement of pressure, flow, temperature, and level to support effective VOC treatment, even in harsh marine environments characterized by salt spray, vibration, high humidity, and wide temperature fluctuations. Designed for long-term offshore operation, these instruments enable stable system control and help optimize treatment efficiency.
Certified to CCS, DNV, ABS, ATEX, IECEx, CE, EAC, and RoHS standards, Micro Sensor’s measurement solutions are trusted worldwide to support safer operations and more sustainable shipping.
Pressure Measurement
In marine VOC treatment systems, pressure monitoring is critical to adsorption efficiency, combustion performance, and overall system safety.
|
|
|
|
⭐ High-Accuracy, High-Reliability Pressure Transmitters
Measuring range: –100kPa~100MPa
Accuracy options: ±0.075%FS / ±0.05%FS / ±0.5%FS / ±0.1%FS
Output signals: 4–20mA / 0–10V DC / HART / RS485 / Bluetooth
Vibration resistance: up to 20g, 20Hz–500 Hz
IP rating: IP65 / IP67
Certifications: CCS, ABS, BV, DNV, KR, LR, NK, RS, ATEX, IECEx, CSA, NEPSI, PCEC, EAC, PAC, CE, RoHS
Application Value
| Measurement Point | Purpose | Operational Benefit |
| Flue gas inlet/outlet pressure | Control system load | Higher treatment efficiency |
| RTO chamber pressure | Prevent overpressure and flashback | Enhanced system safety |
| Adsorption tower differential pressure | Detect blockage and regeneration timing | Reduced unplanned downtime |
In addition, pressure switches are commonly used for interlocking protection at critical points. With fast response and compact design, they serve as the final safeguard for system safety.
Level Measurement
Marine VOC treatment systems require reliable level monitoring in units such as condensate tanks, spray liquid systems, and cooling water reservoirs. Our level measurement portfolio covers multiple measurement technologies, enabling optimal selection for different installation conditions and process requirements.
|
|
⭐ Submersible Level Transmitters
Measuring range: 0–200m
Accuracy: ±0.075%FS / ±0.05%FS / ±0.25%FS / ±0.1%FS
Output: 4–20mA / Modbus
IP rating: up to IP68
Operating temperature: –20℃ to 80℃ (marine liquid environments)
⭐ Radar Level Transmitters
Measuring range: 0–150m
Accuracy: up to ±2mm
Excellent resistance to vapor and condensation interference
Application Value
・Real-time condensate level control
・Stable level regulation in spray towers
・Overflow protection and dry-run protection
Temperature Measurement
The oxidation reactions and adsorption–desorption cycles in VOC treatment systems require precise temperature control and long-term stability.
|
|
⭐ RTD / Thermocouple Temperature Transmitters
Temperature range: –200℃ to 1600℃
Accuracy: up to ±0.1%FS
Outputs: 4–20mA / HART / mV / Ω
Vibration resistance: up to 10g, 10Hz–1000Hz
Protection rating: up to IP67
Certifications: CCS, ABS, DNV, CE, RoHS, etc.
Application Value
| Process | Purpose |
| RTO combustion chamber | Precise control of 800–900℃ reaction temperature, directly affecting VOC destruction efficiency |
| Desorption process | Control of adsorbent regeneration temperature to prevent thermal degradation of activated carbon or zeolite |
| Condensation stage | Monitoring heat transfer efficiency to improve recovery rates |
Flow Measurement
Different stages of marine VOC treatment systems impose distinct requirements on flow measurement, depending on the process medium, flow range, and required accuracy. To meet these diverse needs, Micro Sensor offers a range of flow measurement technologies—including electromagnetic, insertion, Coriolis mass, and vortex flowmeters—suitable for flue gas, process gases, liquids, and steam.
![]() |
|
|
|
⭐ Electromagnetic Flowmeters
Designed for conductive liquids such as cooling water, condensate, and spray media
・Nominal diameters: DN3–DN2400
・Accuracy: up to ±0.2%
・Outputs: HART / RS485 / 1–5V / Profibus-DP/PA / frequency, pulse, relay
・IP rating: up to IP68
・Certifications: CCS, ATEX, EAC, PCEC, CNEX, SIL, CE
Application Value
Flow monitoring in condensation recovery systems
Stable control of spray circulation
Enhanced condensation efficiency
⭐ Coriolis Mass Flowmeters
・Ideal for high-accuracy measurement of VOCs, fuel gas, and desorption gases
・Accuracy: up to ±0.15%FS
・Simultaneous measurement outputs for mass flow, density, and temperature
・Low sensitivity to variations in viscosity and temperature
・Suitable for complex VOCs mixtures
Application Value
・Precise control of desorption gas flow to optimize regeneration efficiency
・Stable fuel gas supply for enhanced RTO combustion performance
・Density-based diagnostics for automatic compensation of media variations
・Enhanced overall energy efficiency, especially in marine VOC systems with highly variable operating conditions and unstable media composition
⭐ Vortex Flowmeters
Suitable for versatile flow measurement of steam, compressed air, and selected gases and liquids.
・Accuracy: up to ±1%
・Wide turndown ratio
・No moving parts, excellent vibration resistance
・Operating temperature: –40℃ to 550℃ (varies by configuration)
Appliation Value
・Steam flow monitoring in VOCs regeneration systems
・Combustion air and process gas flow regulation
・Air and steam balance control in auxiliary power systems
Renowned for their robust construction, durability, and low maintenance, vortex flowmeters are especially well suited for continuous measurement during extended marine operations.












Copyright © 2026 MICRO SENSOR CO., LTD