Hydrology
Reservoir, river level and flow monitoring
Micro Sensor offers advanced digital control solutions for water supply, wastewater treatment and water resource fields.
Urban underground drainage network and municipal water supply system monitoring
Open channels, pipes and pump station monitoring in agricultural irrigation
Real-time collection of reservoir water level, rainfall, and other information at dam monitoring points. Based on the changes in water level and the maximum capacity of the dam, calculations are made, and warnings and alarms are issued when the water level rises above the alert value.
Details >Monitor liquid level and flow data within the river channel. Issue a warning when the water level is about to exceed the river warning line. Additionally, water quality sensor can be installed to report data such as pH value and turbidity to the relevant department's monitoring center when these values exceed normal levels. This monitors water quality, protects the river water environments, and provides data support for the supervision of illegal discharge and leakage.
Details >Pressure, flow, and liquid level monitoring instruments are deployed in locations such as water tanks, pipelines, and water inlets/outlets. This helps to manage the macro-control of production data in the water plant, ensuring smooth operation and normal production.
Details >Collect status data such as water level in the storage tank, pipeline pressure, and flow within the pumping station, and transmit the data to the platform via wireless networks. When anomalies are detected, timely alarms are issued and fault information is sent to the staff to ensure the normal operation of the water supply system.
Details >Range: 0.4bar~30bar
Output Signal: 4mA~20mA DC+HART
-1bar...0~0.1bar…1000bar
Accuracy: ±0.15%FS (Typ.)
3.5, 7, 10, 20, 35, 70, 100, 200mH2O
Accuracy: ±0.1%FS (Typ.)
Range: 0.4bar~30bar
Output Signal: 4mA~20mA DC+HART
Working Temperature: -10℃ ~85℃
Temperature Ranges: -200℃…0℃~ 500℃
Accuracy: ±1.0%FS, ±0.5%FS, ±0.25%FS
Flange type: DN6~DN1600
Measurement Accuracy: ±0.2%(DN10~DN350); ±0.5%(DN6~DN1600)