Monosilicon Hygienic Pressure Transmitter
Pressure type: Gauge
Range: 0.1bar~25bar
Output signal: 4~20mA, 4~20mA+HART, Modbus-RTU/RS485 and others
Reference accuracy: ±0.2% upper range limit, maximum ±0.5% upper range limit
New Product Change Notice (PCN) effective Jan 1, 2025. MICROSENSOR appreciate your understanding.
MTM100R
Used For
Chemical industry, Energy and power generation, Marine and shipbuilding, HVAC systems
Leave a MessageMTM100R RTD Temperature Sensor incorporates a PT100 or PT1000 platinum resistance element, compliant with IEC 60751, housed in a mineralinsulated (MI) sheath. The product has a slim form factor, fast thermal response, and excellent resistance to mechanical stress as well as environmental adaptability. MTM100R is a high-performance Resistance Temperature Detector (RTD) engineered for environments where accuracy and reliability cannot be compromised.
Features
• Compatible with transmitter modules to enhance measurement accuracy, reliability, and system integration.
• Modular design allows for various specifications and compatibility with thermowells.
Image:
MTM100R RTD Temperature Sensor incorporates a PT100 or PT1000 platinum resistance element, compliant with IEC 60751, housed in a mineralinsulated (MI) sheath. The product has a slim form factor, fast thermal response, and excellent resistance to mechanical stress as well as environmental adaptability. MTM100R is a high-performance Resistance Temperature Detector (RTD) engineered for environments where accuracy and reliability cannot be compromised.
Features
• Compatible with transmitter modules to enhance measurement accuracy, reliability, and system integration.
• Modular design allows for various specifications and compatibility with thermowells.

Pressure type: Gauge
Range: 0.1bar~25bar
Output signal: 4~20mA, 4~20mA+HART, Modbus-RTU/RS485 and others
Reference accuracy: ±0.2% upper range limit, maximum ±0.5% upper range limit

3, 5, 7, 10, 20, 35, 70, 100, 200mH2O
Accuracy: ±0.1%FS (Typ.)
HART Protocol
DNV approved for ship use

0bar~0.35bar...35bar
Accuracy: ±0.5%FS
Oxygen DP Measurement


Wind turbines require a control system to optimize the direction of the turbine in accordance with the wind direction (yaw control) and adjust the angle of the blades (pitch control). This control system is completed by the cylinder system, based on the hydraulic principle, in which the pressure sensor plays a crucial role.
more info...
Pressure transmitters are used not only to measure the pressure inside the tank but also to measure the absolute pressure of the tank body and the pressure before and after the cryogenic pump, ensuring the safe operation of the system. Differential pressure measurement is the most common and reliable method for measuring the liquid level of cryogenic high-pressure bulk storage tanks.
more info...
Ballast tank level monitoring achieves precise control of the ballast water system by using equipment such as electromagnetic flowmeters, level transmitters, and pressure transmitters to monitor data on inflow, tank liquid level, and pressure.
more info...
The pressure-release pond can regulate the pressure of the water supply network. It adjusts the pipe network pressure by increasing or decreasing the water volume. The pond maintains the pipelines at a normal level. At various stages of the pressure-release pond, different instruments need to be installed.
more info...