Differential Pressure Transmitting Controller
Range: 0bar~0.35bar... 35bar
Display: 4 digit 0.56 inch 14-segment LED
Output: 4~20mA DC, 0~10V DC
MPM280
Used For
Gas & Liquid Pressure Measurement, Pressure Meter, Liquid Pressure System and Switch
Leave a MessageMPM280 piezoresistive pressure sensor is made of stainless steel, 316L, giving long-term stability for a range of OEM applications. It is filled with silicon oil. MPM280 has strong interchangeability, such as shape, installation size, and sealing method. It is widely compatible with stainless steel and FKM materials. With the compensation temperature ranging 0~50 ℃,MPM280 pressure sensor can work ans stored in -40~125 ℃.
Feature
• Φ19mm OEM pressure element
• Wide Pressure Range: 0bar~0.2bar...700bar
• Measuring various fluid media
• Negative pressure measurement lowest to -1bar
Electrical Performance
• Linearity: ±0.25 (Typ.)
• Long-term stability: ±0.2 %FS/Year (Typ.)
• Storage temp. range: 40~125
• Working temp. range: 40~125
Image:
MPM280 piezoresistive pressure sensor is made of stainless steel, 316L, giving long-term stability for a range of OEM applications. It is filled with silicon oil. MPM280 has strong interchangeability, such as shape, installation size, and sealing method. It is widely compatible with stainless steel and FKM materials. With the compensation temperature ranging 0~50 ℃,MPM280 pressure sensor can work ans stored in -40~125 ℃.
Feature
• Φ19mm OEM pressure element
• Wide Pressure Range: 0bar~0.2bar...700bar
• Measuring various fluid media
• Negative pressure measurement lowest to -1bar
Electrical Performance
• Linearity: ±0.25 (Typ.)
• Long-term stability: ±0.2 %FS/Year (Typ.)
• Storage temp. range: 40~125
• Working temp. range: 40~125
Range: 0bar~0.35bar... 35bar
Display: 4 digit 0.56 inch 14-segment LED
Output: 4~20mA DC, 0~10V DC
3.5, 7, 10, 20, 35, 70, 100, 200mH2O
Accuracy: ±0.1%FS (Typ.)
HART Protocol
1 2 5 10 20 50 100 200mH2O;
Accuracy: +0.25%FS(yp.)
4~20mADC,0~10/20mADC,0/1~5/10VDC
Accuracy:±0.075%FS
Range: 0.4bar~30bar
Output Signal: 4mA~20mA DC+HART
Working Temperature: -10℃ ~85℃ , -10℃ ~70℃ (with LCD display)
The normal operation of fire-fighting water pipeline plays an important role in safeguarding citizens' personal and property safety. Monitoring instruments are installed at each monitoring point of the fire protection pipeline to monitor pressure and level data in real time, so that when an error occurs, faults are located in time and alarms are given to facilitate staff maintenance and processing.
more info...The plasma in a plasma cleaning machine is a state of matter, usually composed of process gases. Therefore, specially designed pressure transmitters must be installed in the relevant gas circuits of the plasma cleaning system to monitor and provide feedback on production data.
more info...Pressure transmitters are used not only to measure the pressure inside the tank but also to measure the absolute pressure of the tank body and the pressure before and after the cryogenic pump, ensuring the safe operation of the system. Differential pressure measurement is the most common and reliable method for measuring the liquid level of cryogenic high-pressure bulk storage tanks.
more info...Real-time collection of reservoir water level, rainfall, and other information at dam monitoring points. Based on the changes in water level and the maximum capacity of the dam, calculations are made, and warnings and alarms are issued when the water level rises above the alert value.